Įrankiai
20-29- Šepetinės šlifavimo staklės WOODLAND MACHINERY (naujos)
UAB Medienos staklės
15 atsiliepimai
4130 €
21-80- Diskinių pjūklų galandimo staklės RS WOOD-CMC (naujos)
UAB Medienos staklės
15 atsiliepimai
5464 €
21-80-027 Diskinių pjūklų galandimo staklės HOLZMANN MTY 8-70
UAB Medienos staklės
15 atsiliepimai
1 €
20-13-300/600 Šlifavimo popierius šepetinėms šlifavimo staklėms (naujas)
UAB Medienos staklės
15 atsiliepimai
25 €
21-80-029 Galandimo staklės tiesiems peiliams HOLZMANN MS 7000
UAB Medienos staklės
15 atsiliepimai
1 €
Skaitmeninis daugiafunkcinis testeris | išmanus | TRUE RMS (81772)
Sthor
9,69 €
Į parduotuvę Prekės aprašymas:
SMART UNIVERSAL TRUE RMS METER. 81772. Mark. Sthor. Symbol. 81772. Series. GRH. Dimensions. 123x58x28 mm. Material. ABS. Application. electric. Operating temperature range. 0~40 C. Storage temperature. -10 ~ +50 C. Power supply. battery. Battery type. 2x1.5V; AAA. Mass. 0.075 kg. Display type. LCD. Data Hold. Yes. Circuit continuity test. 0-50. Conduction test. Yes. LED backlight. YES. Flashlight function. NO. Operating relative humidity Rh. <75%. Low battery indicator. Yes. AC voltage measurement. 0-600 V a.c.. DC voltage measurement. 0-600 V d.c.. Direct current. 0-10A. Resistance measurement. 0-60 M. Alternating current. 0-10A. TRUE RMS. Yes. Automatic measurement range. Yes. Sound signal. Yes. Display range. 5999. Automatic shutdown. 15 min. Non-contact NCV AC voltage detection. Yes. Smart universal meter by STHOR, symbol 81772, with TRUE RMS function and automatic range for each measurement. The meter will not only automatically select the measurement range, but will also independently determine whether we are currently measuring resistance, circuit continuity, direct or alternating current voltage. This makes the meter very easy to use. In standard meters, before the measurement, we must set the appropriate measurement range and measurement type ourselves. In this meter, after turning it on, you just need to place the measuring probes, e.g. on the battery poles, and then read the result.. Basic measurements. AC voltage measurement: A.C. 0-600V, TRUE RMS. DC voltage measurement: D.C. 0-600V. measurement of alternating current: A.C. 0-10A, TRUE RMS. measurement of direct current intensity: D.C. 0-10A. resistance measurement: 0-60M. circuit continuity test: 0-50. Additional measurements. non-contact detection of alternating voltage: NCV. Measurement accuracy. An example of determining accuracy for measuring AC voltage. Calculations for the measurement result: 235V. measurement accuracy of the 81772 meter for this range is: (1.0% + 3), resolution 0.1V. Measurement error calculation formula: (measurement result x 1.0%) + 3 x resolution. calculations: (235 x 1.0%) + 3 x 0.1 = 2.35 + 0.3 = 2.65V. The actual result taking into account the measurement error for the indication 235V = 235 2.65V. result taking into account the measurement error to indicate the DC voltage measurement: 12V = 12 0.09V. result taking into account the measurement error to indicate the measurement of alternating current: 8A = 8 0.164A. A table with the resolution and accuracy for a given measurement can be found in the user manual.. Built-in features. TRUE RMS - a meter with this function calculates the real effective value of alternating voltage and current for both sinusoidal and non-sinusoidal waveforms. The device first measures the actual value of the sine wave at several time intervals then squares the measurement results sums them calculates the average and finally squares the average result. The measurement result is the real effective value of alternating voltage/current, even for a deformed sine wave or square wave;. NCV - non-contact detection of alternating voltage using the inductive method. The meter detects the presence of voltage in the insulated wire using the NCV sensor on the front of the device;. AUTO - automatic adjustment of the measurement range. When measuring unknown values using a meter with a manual range change using a knob, measurements should be performed sequentially from the largest range to the range giving the most accurate result - otherwise you risk damaging the device. However, in the case of a multimeter with the AUTO function, it is enough to perform one measurement and the meter will automatically find the optimal range;. SMART - automatic recognition of the measurement type. The meter will recognize itself whether we are measuring direct or alternating current voltage. If no voltage is present, the meter automatically switches to circuit resistance measurement mode;. DATA HOLD - keeping the currently measured value on the display.. Additional information. LCD display, maximum displayed result: 5999. screen backlight. audible signal in the continuity test for resistance below 50. The set includes measurement probes with a length of 12 cm. cable length with probes: 84 cm. wire diameter with insulation: 3.5 mm. ABS plastic housing. automatic shutdown of the meter after 15 minutes of inactivity. low battery indicator. power supply: two 1.5 V (AAA) batteries